Now in Beijing, Zhengzhou, Shenyang, Chongqing and other production bases

Set Research and development, production, sales, technical services as one



24-hour hotline

13925840771

CN

Home >> Product >>Grouting series >> Epoxy resin potting glue
Product Detail

Epoxy resin potting glue

No price
Collect
  • DETAILS

modified epoxy anchoring Glue [Reinforcement glue]

u0026nbsp;

u0026nbsp;

< span style='padding: 0px; margin: 0px; text-align: left; transition: all 0.2s linear 0s; font-family: 宋体;'>Contact:u0026nbsp;13925840771u0026nbsp;Manager Zhang

.Features :

u0026nbsp;

1, fast load bearing, large anchoring force, aging resistance , Excellent chemical resistance and water resistance.

u0026nbsp;

2, the amount of slip is small, can Timely control the delamination and deformation of the substrate, and the shrinkage rate after curing can be reduced to1%Below.

u0026nbsp;

.Application range:

u0026nbsp;

1. It is used for the anchoring construction of steel bar in concrete, brick wall, rock and other base materials.

u0026nbsp;

2, applied to various load-bearing, Non-load-bearing bolts and concrete, brick wall, rock and other base materials planted reinforcement anchor construction.

u0026nbsp;

implementation standardsu0026nbsp; YB/T9261-98

u0026nbsp;

.Performance index:

u0026nbsp;

u0026nbsp;

< tbody>

constraints Ribbed steel bars and C30 Ф25 under drawing conditions

colloid< /span>

Performance

tensile Strength Mpa

≥30

flexural strength Mpa

≥50

Compressive strength Mpa

≥60

bonding

Performance

Steel----Steel Shear Strength Mpa

≥16

< span style='padding: 0px; margin: 0px; text-align: left; transition: all 0.2s linear 0s; font-family: Times New Roman; font-size: 14px;'>steel----steel tensile strength Mpa

≥33

≥11

The bond strength of concrete Mpa C60 Ф25

≥17

< span style='padding: 0px; margin: 0px; text-align: left; transition: all 0.2s linear 0s; font-family: Verdana; color: rgb(85, 85, 85); font-size: 12px;' >u0026nbsp;

Rebar planting parameter table:

u0026nbsp;

1, drilling diameterD selected by steel bar diameterd and the surface state of the steel bar.

u0026nbsp;

u0026nbsp;d≤12mmtakeD=d 4mm.

u0026nbsp;

u0026nbsp;12mm<d<20mmtakeD=d 6mm.

u0026nbsp;

u0026nbsp;d≥20mmtakeD=d 8mm.

u0026nbsp;

Theoretical usage of rebar glue:

u0026nbsp;

Rebar diameter (mm)

< /td>

Aperture (mm)

Hole depth (mm)

Injection volume MI (2/3v)

Theory Quantity (root)

< p style='padding: 0px; margin: 0px; text-align: left; transition: all 0.2s linear 0s; line-height: 20px;'>Remarks

8

12

80

6.03

59.7

10d

×
seo seo